无码人妻一区二区三区在线视频|妺妺窝人体色www在线小说|少妇又紧又色又爽又刺激视频|精品国产一区二区三区久久影院

歡迎來到北京豫維科技有限公司網站!

熱門關鍵詞:蘇瑪罐,原子吸收分光光度計,環(huán)境監(jiān)測產品,液相色譜,色譜柱。

產品中心您現(xiàn)在的位置:首頁 > 產品展示 > 液相配件 > 去除裝置 > Dionex CRD碳酸鹽去除裝置

Dionex CRD碳酸鹽去除裝置

更新時間:2019-11-18

簡要描述:

Dionex CRD碳酸鹽去除裝置
從抑制洗脫液流通過擴散通過碳酸酯的選擇性透氣膜的壁除去二氧化碳。

  免費咨詢:010-61755520

  發(fā)郵件給我們:yuweichina86@163.com

Dionex CRD碳酸鹽去除裝置

 

Thermo Scientific的戴安™酸鹽去除裝置(CRD 180,200和300)從抑制洗脫液流通過擴散通過碳酸酯的選擇性透氣膜的壁除去二氧化碳。與碳酸洗脫液系統(tǒng)的戴安CRD 300降低了背景信號,以幾乎相同的水平作為氫氧化物洗脫液。抑制器后鉛垂,二氧化碳傳輸是由堿性溶液的逆流輔助。

戴安CRD 180和200用于從氫氧化物洗脫液系統(tǒng)中除去碳酸優(yōu)化
盡量減少使用戴安CRD 180或200可以提高量化碳酸鹽
戴安CRD 180的減小的膜長度為根據4微米樹脂柱優(yōu)化
戴安CRD 300的增加的膜長度為碳酸鹽淋洗液系統(tǒng)進行了優(yōu)化
減少與戴安CRD 300結果基線為碳酸鹽淋洗液系統(tǒng)更高的靈敏度
與一戴安CRD 300碳酸背景消除增加了線性范圍

 

 

Dionex CRD碳酸鹽去除裝置

訂貨信息:

CRD 180   (0.4 mm)                                  079960     
CRD 200 (4 mm)     062983
CRD 200 (2 mm)     062986
CRD 200 (0.4 mm)     072054
CRD 300 (4 mm)     064637
CRD 300 (2 mm)     064638
CRD 300 (4 mm) with Peristaltic Pump Kit     064905
CRD 300 (2 mm) with Peristaltic Pump Kit     064906
Santoprene Tubing for Peristaltic Pump     068518
Ship Kit for Peristaltic Pump/CRD 300     064911
CRD 300 (4 mm) with VP Vacuum Pump Kit     068475
CRD 300 (2 mm) with VP Vacuum Pump Kit     068474

 

Reduces Carbonate for Improved Sensitivity

The Thermo Scientific Dionex Carbonate Removal Device (CRD 180, 200 and 300) remove carbon dioxide from the suppressed eluent stream by diffusion through the walls of a carbonate selective gas permeable membrane. With carbonate eluent systems the Dionex CRD 300 reduces the background signal to nearly the same levels as that of hydroxide eluents. Plumbed after the suppressor, the carbon dioxide transfer is aided by a countercurrent flow of basic solution.

  • The Dionex CRD 180 and 200 are optimized for the removal of carbonate from hydroxide eluent systems

  • Minimizing carbonate using the Dionex CRD 180 or 200 can improve quantification

  • The reduced membrane length of the Dionex CRD 180 is optimized for columns based on 4 μm resins

  • The increased membrane length of the Dionex CRD 300 is optimized for carbonate eluent systems

  • Reducing the baseline with a Dionex CRD 300 results in higher sensitivity for carbonate eluent systems

  • Elimination of the carbonic acid background with a Dionex CRD 300 increases the linearity range

Dionex CRD 200 Carbonate Removal Device

Exposure to carbon dioxide can cause samples to become contaminated with carbonate. High levels of carbonate originating from dissolved carbon dioxide can interfere with the accurate determination of analytes of interest, such as sulfate and nitrite. The Dionex CRD 200 is a device used to remove the carbonate peak contributed by the sample.

The Dionex CRD 200 can be installed easily in any Thermo Scientific Dionex IC system equipped with an eluent generator, Thermo Scientific Dionex CR-ATC Continuously Regenerated Anion Trap Column, and Thermo Scientific Dionex AERS 500 Anion Electrolytically Regenerated Suppressor or Thermo Scientific Dionex ACES 300 Anion Capillary Electrolytic Suppressor, and requires no reagents or software control. The Dionex CRD 200 is a low-dispersion devices designed specifically for use with hydroxide- and borate-based chemistries using Thermo Scientific Dionex columns.

The Dionex CRD 200 is available in three formats. The Dionex CRD 200 (4 mm) supports carbonate removal from standard bore systems, while the Dionex CRD 200 (2 mm) supports carbonate removal from microbore systems; the Dionex CRD 200 (0.4 mm) supports carbonate removal from capillary-scale systems at flow rates of 5 – 30 μL/min.

 

A significant amount of carbonate is removed using the Dionex CRD 200 Carbonate Removal Device.

Dionex CRD 300 Carbonate Removal Device

Carbonate eluents are suppressed to relatively low-conductivity carbonate acid, but the residual conductivity of the carbonic acid has several undesirable effects. Carbonic acid can mask small peaks, decreasing the limit of detection (LOD) during trace analyses. In a background of carbonic acid, the linear range of most species is limited, and the residual background conductivity creates a large void dip which can hamper the integration of early eluting species. The CRD 300 is a device used to remove the carbonic acid from the suppressed eluent, providing hydroxide-like detection to systems using carbonate eluents.

The Dionex CRD 300 can be installed easily in any Dionex IC system running carbonate as an eluent with a Dionex AERS 500 suppressor. The Dionex CRD 300 requires either a constant flow of basic solution from a peristaltic pump or evacuation by a vacuum pump. The Dionex CRD 300 is designed specifically for use with carbonate eluent based chemistries using Dionex columns.

The Dionex CRD 300 is available in two formats. The Dionex CRD 300 (4 mm) supports carbonate removal from standard bore systems, while the Dionex CRD 300 (2 mm) supports carbonate removal from microbore systems.

 

Background signal is reduced using the Dionex CRD 300 Carbonate Removal Device.

Dionex CRD 180 Carbonate Removal Device

The Dionex CRD 180 is a version of the Dionex CRD 200 that has reduced internal volume. This facilitates operation in conjunction with 4 μm resin packed capillary columns without unacceptable loss of peak efficiency. However the Dionex CRD 180 has less capacity for the removal of carbonate than the Dionex CRD 200, and is therefore not recommended for use with columns packed with resin larger than 4 μm.

The Dionex CRD 180 can be installed easily in a Dionex Capillary IC system equipped with an eluent generator, Dionex CR-ATC Continuously Regenerated Anion Trap Column, and Dionex ACES 300 suppressor. The Dionex CRD 180 requires no reagents or software control. The Dionex CRD 180 is an ultra-low-dispersion device designed specifically for use with hydroxide-based chemistries using Dionex columns.

The Dionex CRD 180 is only available in capillary (0.4 mm) format for use with 0.25 mm and 0.4 mm capillary columns. Microbore and standard-bore systems using 4 μm resin packed columns should use the Dionex CRD 200.

Dionex Carbonate Removal Device CRD 180 Specifications
Hardware Dimensions
( h × w × d)
11.3 cm × 9.3 cm × 2.1cm
(4.5 in. × 3.7 in. × 0.8 in.)
Void Volume0.4 mm: ~1 μL

 

Dionex Carbonate Removal Device CRD 200 Specifications
Hardware Dimensions
( h × w × d) (4 mm and 2 mm)
2.0 cm × 4.4 cm × 7cm
(0.8 in. × 1.7 in. × 2.8 in.)
Hardware Dimensions
( h × w × d) (0.4 mm)
11.3 cm × 9.3 cm × 2.1cm
(4.5 in. × 3.7 in. × 0.8 in.)
Void Volume2 mm: ~40 μL
4 mm: ~200 μL
0.4 mm: ~2 μL

 

Dionex Carbonate Removal Device CRD 300 Specifications
Hardware Dimensions
( h × w × d)
2.0 cm × 4.4 cm × 7cm
(0.8 in. × 1.7 in. × 2.8 in.)
Void Volume2 mm: 80 μL
4 mm: 225 μL

 

 

    沒有相關產品信息...

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數(shù)字),如:三加四=7
国产欧美久久久精品影院| 国产绳艺sm调教室论坛 | 无码人妻一区二区三区在线| 亚洲中文字幕无码久久2020| 欲妇荡岳丰满少妇岳| 亚洲人成网7777777国产| 午夜无码人妻av大片色欲| 国外人妻视频免费播放| 怡红院免费的全部视频| 国产成人麻豆精品午夜福利在线| 少妇脱了内裤让我添| 久久国产精品无码一区二区三区| 久青草国产在视频在线观看| 精品国产aⅴ无码一区二区| 国产欧美性成人精品午夜| 猫咪免费人成网站在线观看| 国产精品久久久久影院| 三级三级一区二区三区| 国产高潮流白浆啊免费a片动态| 女人扒开屁股桶爽30分钟| 秋霞av鲁丝片一区二区| 国产香蕉视频在线播放| 日日橹狠狠爱欧美超碰| 人妻中文乱码在线网站| 日韩AV中文无码影院| 国产精品无码专区在线观看| 18禁裸乳无遮挡啪啪无码免费| 成人午夜在线观看日韩| a级毛片免费全部播放| 妺妺跟我一起洗澡没忍住| 国产激情综合五月久久| 人人澡 人人澡 人人看| 图片小说视频一区二区| 久久99精品国产99久久| 无码av最新无码av专区| 国产成人无码a区在线观看视频app| 国产日韩精品中文字无码| 无码超级大爆乳在线播放| 国产后入又长又硬| h无码精品3d动漫在线观看| 太粗太深了太紧太爽了动态图男男|